top of page

Exposure System
-Continuous Flow

for 24-well inserts

24-24-title.png

In vitro inhalation exposure modules for 24-well inserts

The VITROCELL® Exposure Systems are designed for the direct exposure of cell cultures to airborne substances such as gases, complex mixtures, nanoparticles and fibers. The system simulates the human exposure situation.

Untitled-11.png

VITROCELL® 24/24

Exposure module for 24-well sized inserts with electronic heating. 6 doses with 4 replicates.

Untitled-13.png

VITROCELL® 24/48

VITROCELL® 24/48 incl. rack, locking device and dilution systems.

VITROCELL® 24/24

for 24-well sized inserts

VITROCELL® 24/24

24-24-title.jpg.jpeg

VITROCELL® 24 cultivation and exposure system for 24-well sized cell culture inserts. Suitable for COSTAR®and ThinCert® brands.

6 dilutions and controlled guidance of the aerosol to 4 wells per dilution make the VITROCELL® an efficient and extremely powerful analysis tool.

VITROCELL® 24/24 Base module

24-24-base-module-720x480.jpg.jpeg

The base module is made of electropolished stainless steel. An optional transparent control window facilitates the external monitoring of media levels and may be easily removed from the integrated heating base. Temperature can be programmed individually.

VITROCELL® 24/24 Aerosol exposure top

24-24-aerosol-exposure-top-720x480.jpg.jpeg

Special sealing and connection mechanisms guarantee a hermetic connection of the base module with the aerosol exposure top.

The aerosol exposure top guides the test atmosphere at an individually controlled flow rate to each cell culture membrane.

VITROCELL® 24/24 Controlled inlet flow

principle-trumpets-720x480.jpg.jpeg

VITROCELL® exposure systems have been specifically designed and engineered to give researchers the possibility of directly exposing mammalian cells or tissue at the air/liquid interface. Thus, all cell types cultivated on microporous membranes can be used. This approach allows for more credible and authentic results than by submerged exposure due to a closer replication of the human physiology.

VITROCELL® 24/24 Features

24-24-title.jpg.jpeg
  • Supplied with dynamic double-jet dilution system for 6 dilutions with 4 replicates

  • 24-wells for COSTAR® and ThinCert® inserts

  • Single supply to each cell culture membrane

  • Base module and aerosol exposure top are autoclavable

  • Integrated, sensor-controlled heating plate

  • Option: Control window for monitoring culture medium levels

VITROCELL® 24/48

for 24-wel sized inserts

VITROCELL® 24/48
Stainless Steel Exposure Module

24-48-title-climatic-chamber-xt-1.jpg (2).jpeg

The new generation of Climatic Chambers is enlarged to accomodate all required components for the operation of the VITROCELL® 24/48 System. More space faciltates the handling of dosimetry tools inside the chamber.

The extended version features an integrated humidification system with pre-heating of dilution air. The flow ­controllers are moved to the inside of the chamber for constant ­temperature and increased humidity output.

VITROCELL® 24/48 Base modules

24-48-base-module-720x480.jpg.jpeg

The base module with 48 wells (24-well-size) is made of electropolished stainless steel. An optional transparent control window facilitates the external monitoring of media levels and may be easily removed from the integrated heating base. Temperature can be programmed individually.

VITROCELL® 24/48 Aerosol exposure top

24-48-exposure-top.jpg.jpeg

Special sealing and connection mechanisms guarantee a hermetic connection of the base module with the aerosol exposure top.

The aerosol exposure top guides the test atmosphere at an individually controlled flow rate to each cell culture membrane.

VITROCELL® 24/48 Controlled inlet flow

principle-trumpets-720x480.jpg.jpeg

VITROCELL® exposure systems have been specifically designed and engineered to give researchers the possibility of directly exposing mammalian cells or tissue at the air/liquid interface. Thus, all cell types cultivated on microporous membranes can be used. This approach allows for more credible and authentic results than by submerged exposure due to a closer replication of the human physiology.

VITROCELL® 24/48 Insert size

24-well-sized-inserts-about.jpg.jpeg

The module has been designed for 24-well sized cell culture inserts.

VITROCELL® 24/48 Features

24-48-title-climatic-chamber-xt-1.jpg (2).jpeg
  • Supplied with dynamic double-jet dilution system for 8 dilutions with 6 replicates

  • 48-wells for COSTAR® and ThinCert® inserts

  • Single supply to each cell culture membrane

  • Base module and aerosol exposure top are autoclavable

  • Integrated, sensor-controlled heating plate

  • Optional climatic chamber