top of page

Exposure System
-Continuous Flow

For 35mm Petri dishes

vitrocell-6-3-title.png

In vitro inhalation exposure modules for suspension cells

VITROCELL® modules enable direct exposure in Petri dishes with integrated magnetic stirring for optimal contact with the test substance.

ames-3-up.png

VITROCELL® SC3 Exposure Module for Suspension Cells

Exposure module for 3 Petri dishes with 35mm diameter.

ames-4-up.png

VITROCELL® SC4 Exposure Module for Suspension Cells

Exposure module for 4 Petri dishes with 35mm diameter.

VITROCELL® SC 3 Exposure Module for Suspension Cells

For 3 Petri dishes (35 mm size)

VITROCELL® SC3 Exposure Module for Suspension Cells

ames-3-title.jpg.jpeg

The VITROCELL® SC 3 module system has been specifically designed and engineered to facilitate the research of suspension cells direct exposure to airborne substances such as gases, complex mixtures, nanoparticles and fibers. It has a unique magnetic stirring capability.

Normally two modules are required: one module for exposure to the substances and a second module for clean air control. The capacity can be easily increased by adding more modules. Each module can receive a different dose concentration, so that a complete dose / response profile can be obtained in one experiment. The suspension cells are directly exposed in stirred media using controlled flow rates of the aerosol. After exposure, the cultures are further processed.

VITROCELL® SC 3 Base module

ames-3-base-module-720x480.jpg.jpeg

This high-quality module with three compartments for 35 mm Petri dishes is made of boron-silicate glass and surface treated aluminum.

VITROCELL® SC 3 Aerosol exposure top

ames-3-aerosol-exposure-top-720x480.jpg.jpeg

Special sealing and connection mechanisms guarantee a hermetic connection of the base module with the aerosol exposure top.

The inlets are available in stainless steel or stainless steel with unique VITROGLIDE surface treatment for lowest adhesion results. The aerosol inlets are connected to the aerosol generation / dilution system and their respective outlets to the vacuum pump.

VITROCELL® AMES 3 Controlled inlet flow

principle-trumpets-720x480.jpg.jpeg

VITROCELL® exposure systems have been specifically designed and engineered to give researchers the possibility of directly exposing mammalian cells or tissue at the air/liquid interface. Thus, all cell types cultivated on microporous membranes can be used. This approach allows for more credible and authentic results than by submerged exposure due to a closer replication of the human physiology.

VITROCELL® SC 3 Features

6-3-stainless-steel.jpg.jpeg
  • Suitable for Petri dishes (diameter 35 mm)

  • Hyperboloid geometry of inlets for optimized particle deposition and distribution

  • Direct flow control for each inlet

  • Base module made of stainless steel for maximum durability

  • Magnetic stirring capability

VITROCELL® SC 4 Exposure Module for Suspension Cells

for 4 Petri dishes (35 mm size)

VITROCELL® SC 4 

ames-4-title.jpg.jpeg

The VITROCELL® SC 4 module system has been specifically designed and engineered to facilitate the research of suspension cells direct exposure to airborne substances such as gases, complex mixtures, nanoparticles and fibers. It has a unique magnetic stirring capability.

Normally two modules are required: one module for exposure to the substances and a second module for clean air control. The capacity can be easily increased by adding more modules. Each module can receive a different dose concentration, so that a complete dose / response profile can be obtained in one experiment. The suspension cells are directly exposed in stirred media using controlled flow rates of the aerosol. After exposure, the cultures are further processed.

VITROCELL® SC 4  Base module

ames-4-base-module-720x480.jpg.jpeg

The module is made of high-quality stainless steel. It has been specifically designed with 4 compartments for 35 mm Petri dishes.

This module is renowned in scientific circles for its reliability and durability.

VITROCELL® SC 4 Aerosol exposure top

ames-4-aerosol-exposure-top-720x480.jpg.jpeg

Special sealing and connection mechanisms guarantee a hermetic connection of the base module with the aerosol exposure unit.

The inlets are available in stainless steel or stainless steel with unique VITROGLIDE surface treatment for lowest adhesion results. The aerosol inlets are connected to the aerosol generation / dilution system and the respective outlets to the vacuum pump.

VITROCELL® SC 4 Controlled inlet flow

principle-trumpets-720x480.jpg.jpeg

VITROCELL® exposure systems have been specifically designed and engineered to give researchers the possibility of directly exposing mammalian cells or tissue at the air/liquid interface. Thus, all cell types cultivated on microporous membranes can be used. This approach allows for more credible and authentic results than by submerged exposure due to a closer replication of the human physiology.

VITROCELL® SC 4 Microbalance Sensor – Additional option

Ames4-SC4-QCM-Vitrocell_6-4_CF_059_microbalance_sensor_Schatten-720x480.jpg.jpeg

VITROCELL® SC 4 Petri dishes

35-mm-petri-dishes-about-1-720x480.jpg.jpeg
  • The module has been designed for 35 mm Petri dishes.

VITROCELL® SC 4 Features

ames-4-title.jpg.jpeg
  • Suitable for Petri dishes (diameter 35 mm)

  • Hyperboloid geometry of inlets for optimized particle deposition and distribution

  • Direct flow control for each inlet

  • Base module made of stainless steel for maximum durability

  • Magnetic stirring capability

  • Option: Quartz Crystal Microbalance

YTK로고

회 사 명 : 주식회사 와이티케이코퍼레이션

대 표 : 김 용 태

주 소 : 경기도 의왕시 이미로 40, B동 508호

​사업자 등록번호 : 857-86-02150

와이티케이코퍼레이션

전 화     : 031-8084-3600

팩 스     : 031-8084-3603

E-mail  : ytk8180@gmail.com 

© Copyright 저작권 보호 대상입니다.

© 2023 by YTK corporation. All Rights Reserved.

bottom of page